CNCGLASS-EVA-Film-Technical-Data

This two-page technical article describes CNCGLASS EVA film as a colorless, translucent poly(ethylene-co-vinyl acetate) sheet in the unprocessed state as it leaves the plant, with clearly stated thickness, width, and density, together with statements on restricted-substance and chemical-registration expectations under European Directive 2011/65/EU (RoHS) and Regulation (EC) No 1907/2006 (REACH). Nominal thickness is offered from 0.38 mm to 0.80 mm, the standard width is 2,400 mm, and density is about 0.95 g/cm³. The figures are indications for unprocessed film; the article does not describe a laminating cycle or a safety-glass evaluation, which are covered for the appropriate grades in the CNCGLASS articles on EVA laminating film. Enquiries can be sent to cnc@cncglass.com.

CNCGLASS-PDLC-Film-Cutting-Electrode-Technical-Note

This technical note describes the workshop method used by CNCGLASS to cut PDLC film and to make the electrode. The sequence covers sheet cutting on a double-position table, preparation of the film edge, silver-paste work on the screen, formation of the electrodes with copper mesh, conductive glue and copper foil, a lead-wire connection method, and a power-on test. A list of the tools and consumables is included, together with workshop details such as a 5 mm edge width, removal of the protective layer for about 6 cm, a 10-minute stir of the silver paste, and, for large-size film, a curing machine set to 113 degrees with a 10-minute bake. Enquiries can be sent to cnc@cncglass.com.

CNCGLASS SGP Interlayer Film Packaging

These photographs show CNCGLASS packing and loading of SafetyGlassPlus SGP ionoplast interlayer film, a super-clear ionoplast interlayer for structural laminated safety glass. The film is packed in wooden export crates on pallets for shipment.

The first photograph shows a wooden crate on a pallet in a warehouse yard, positioned for loading into a delivery truck. The second photograph shows a longer wooden crate, also on a pallet and strapped, beside a forklift and a truck. The third photograph is a closer view of the loading scene, with product and contact details overlaid on the image. Enquiries can be sent to cnc@cncglass.com.

A wooden export crate of SGP interlayer film on a pallet, ready for loading into a delivery truck.
A long wooden packing crate of SGP interlayer film on a pallet beside a forklift and a truck.
Loading a packed crate of SafetyGlassPlus SGP ionoplast interlayer film (Super Clear) for structural laminated safety glass.

CNCGLASS Ionoplast Interlayer Tensile Tear Elongation Mechanical Performance Technical Note

This CNCGLASS technical note presents the mechanical properties of CNCGLASS ionoplast interlayer film with a nominal thickness of 1.54 mm, tested at 23 ± 2 °C and 50 ± 5% RH. Tensile strength was 37.7 MPa (ASTM D638-14, Type I specimen, 50 mm/min crosshead speed, 115 mm grip separation). Elongation at break was 330% (ASTM D412-16 Method A, Die C specimen, 500 mm/min, 25 mm gauge length). Tear strength was 165.4 kN/m (ASTM D624-00 (2012), Type C specimen, 500 mm/min). The note states that it is a performance summary, not a third-party test certificate or a certificate of conformity, and that it does not authorize the use of any third-party laboratory mark.

The note reports that this combination of tensile strength, elongation and tear resistance is intended to support post-breakage performance in structural laminates, including overhead glazing, floor and stair treads, facades, balustrades and other structural glazing applications. Enquiries can be sent to cnc@cncglass.com.

CNCGLASS Ionoplast Interlayer Laminated Glass Optical Performance Technical Note

This CNCGLASS technical note summarizes the optical performance of laminated glass made of 5 mm clear glass, a 0.76 mm CNCGLASS ionoplast interlayer, and 5 mm clear glass. Three specimens, each 100 mm × 100 mm × 10.76 mm, were tested. Visible light transmittance was 90.4%, 90.3%, and 90.4% (GB/T 2680-1994, Clause 3.1). UV transmittance was 0.9%, 0.9%, and 1.0% (GB/T 2680-1994, Clause 3.10). Haze was 0.27%, 0.24%, and 0.19% (GB/T 2410-2008). Yellow index was 0.7, 0.6, and 0.7 (HG/T 3862-2006 (2017)). The note states that it is a performance summary, not a third-party test certificate or a certificate of conformity, and that it does not authorize the use of any third-party laboratory mark.

The note reports that visible light transmittance of 90.3–90.4% shows the 0.76 mm ionoplast interlayer imposes virtually no penalty on light transmission for this 10.76 mm construction; ultraviolet transmittance of 0.9–1.0% means the laminate blocks more than 99% of incident UV radiation; haze of 0.19–0.27% is described as exceptionally low; and the yellow index of 0.6–0.7 is described as effectively near zero, so the laminate remains water-white and colour-neutral. The construction is described as combining daylight clarity with strong UV screening for storefronts, museum glazing, skylights and other vision-critical architectural applications. Enquiries can be sent to cnc@cncglass.com.

CNCGLASS-Ionoplast-Laminated-Glass-8-1.52-8-BS6206-Note

This CNCGLASS technical note summarizes an impact classification under BS 6206:1981 for laminated safety glass made of 8 mm annealed glass, a 1.52 mm ionoplast interlayer, and 8 mm annealed glass. Four specimens, each 865 mm × 1930 mm, were tested; measured thicknesses were 17.55 mm, 17.54 mm, 17.53 mm, and 17.55 mm. The note states that it is a performance summary, not a third-party test certificate or a certificate of conformity, and that it does not authorize the use of any third-party laboratory mark.

Each specimen was struck by a test impactor at drop heights of 305 mm, 457 mm, and 1219 mm, following the procedures in BS 6206, Appendix A, Clause A.4. At 305 mm and at 457 mm, none of the four specimens broke, and they were recorded as Class C and Class B respectively. At 1219 mm, specimen 1 did not break, while specimens 2, 3, and 4 broke safely; all four were recorded as Class A. For the specimens that broke, both glass layers were broken with numerous cracks, no shear or opening developed in the body of the test piece, and the detached-particle mass limits in BS 6206 clause 5.3.3 were met. Under BS 6206:1981, the classification recorded for this sample is Class A, the most severe impact class in that standard, which also covers the lower drop heights. Enquiries can be sent to cnc@cncglass.com.

CNCGLASS-Ionoplast-Interlayers-in-Architecture

This technical article describes ionoplast interlayers, commonly called SGP in architectural practice, as a structural interlayer rather than a laboratory curiosity. After lamination they are stiffer and stronger than conventional PVB, they hold residual capacity when the glass is cracked, and they weather well at exposed edges when the unit is properly detailed. The chemistry is an ionomer sheet, not an ion-exchange membrane for water treatment or a fuel-cell electrolyte; in buildings the film bonds glass plies into a plate that can share load, keep fragments in the frame, and remain optically stable. The article points to high-rise and long-span curtain walls, frameless balustrades, overhead glass, and floors as the settings where the higher modulus is most valuable, and notes low moisture uptake and little yellowing. It also cautions that the autoclave hold must reach the temperature at which the ionoplast flows and wets the glass, and that cost and plant capability still decide whether PVB, EVA, or ionoplast is the right family for a given opening.

CNCGLASS-Ionoplast-Applications-and-Outlook

This technical article explains where ionoplast interlayers belong in laminated glass: they raise the stiffness and residual capacity of the plate, which is a different job from ion-selective membranes used in energy conversion or water purification. The film sits between glass plies and is processed in an autoclave. The article treats structural glass as the core market, including high-rise walls, long-span roofs, fins, floors, and frameless rails, and notes continued use in security and storm stacks as well as marine and other harsh climates. It also states the limits: ionoplast will not replace PVB in everyday windshields or in most acoustic interiors, and it will not replace EVA in decorative or vacuum-furnace work. The outlook is described as strong where glass must act as a structure, a security barrier, or a weathered long-span skin, with growth following process capability and honest specification as much as polymer chemistry.

CNCGLASS-Measuring-Silicone-Membrane-Edge-On-Workshop-Floor

This short video shows a CNCGLASS silicone membrane on cardboard on the workshop floor, with a tape measure run along the edge. The camera moves from a wide view of the sheet to a close view of the tape at the end of the measurement.

A tape measure is run along the edge of a CNCGLASS silicone membrane laid on cardboard on the workshop floor.

CNCGLASS silicone membranes are used for safety glazing vacuuming, including glass lamination with EVA, PVB, SGP, or TPU. A CNC@CNCglass.com watermark runs across the frame. Enquiries can be sent to cnc@cncglass.com.

CNCGLASS-Measuring-Silicone-Membrane-With-Protective-Film

This short video shows a CNCGLASS silicone membrane laid on cardboard on the workshop floor, with clear protective film at one end. Two workers measure the sheet with a tape, and the camera closes in on the tape beside the film.

A CNCGLASS silicone membrane is measured on the workshop floor, with clear protective film at one end.

CNCGLASS silicone membranes are used for safety glazing vacuuming, including glass lamination with EVA, PVB, SGP, or TPU. A CNC@CNCglass.com watermark runs across the frame. Enquiries can be sent to cnc@cncglass.com.